LBSA DALY 100a 15S/16S 48V LiFePO4 Smart BMS with Optional Display or Bluetooth
Download Datasheet
*Please note that display and Bluetooth are sold separately.
Electrical Parameters: Room temperature 25℃, humidity 55%
Daly host program UART to USB Cable required VIEW (Below driver to be installed.
Daly host program Driver TO BE INSTALLED WHEN USING Daly Host Program and UART
Bluetooth APP : Search SMART BMS in your App store ( Android or Apple ) - Bluetooth module required
N0 | DESCRIPTION | SPECIFICATION | UNIT | REMARKS | |
1 | Discharge | Continue discharge current | 100 | A | |
2 | Charge | Charge Voltage | 58.4 |
V | |
Charge current | 50 | A | |||
3 | Over Charge Protection | Over charge detect voltage | 3.75+-0.05 | V | |
Over charge protection delay
|
1
|
S
|
|
||
Over charge release voltage
|
3.55±0.05
|
V
|
|
||
4 | Balance |
Balance detect Voltage
|
3.20
|
V | |
Balance current
|
30±5
|
mA | |||
Balanced opening condition
|
1. On a charge
2. Achieve set balance opening differential pressure
3. Achieve 50mv
|
||||
5 | Over discharge protection |
Over discharge detect
|
2.2±0.1
|
V | |
Over discharge detect delay
|
1 | S | |||
Over discharge release voltage
|
2.
2.3±0.1
|
V | |||
6 | Over Charge current protection |
Over discharge detect
|
150±15 | A |
Can set as required |
Over Charge current detect delay
|
1 | S | Can set as required |
||
Over Charge current protection
release condition |
Off load | Off load | Off load | ||
7 | Over discharge current protection |
Over discharge current detect voltage
|
150±15 | A |
Can set as required |
Over discharge current detect delay
|
1 | S |
Can set as required |
||
Over discharge current
protection release condition |
Off load | Off load | Off load | ||
8 | Short Circuit protection |
Short Circuit protection condition
|
Short circuit of external load | Short circuit of external load | Short circuit of external load |
Short circuit detect delay | 320 | uS | |||
Short circuit protection release | Off load | Off load | Off load | ||
9 | Temp Protect |
Charge Temperature protection degrees | -40~65 | ℃ |
Recover-35 Recover 60 |
Discharge Temperature protection degrees | -40~70 | ℃ |
Recover-35 Recover 60 |
||
Release Condition of temperature protection | Recovery temperature reached and load disconnected | ||||
10 | Means of communication | UART | Display or Bluetooth | ||
11 | Inner Resistance |
Main Circuit Conduct Inner resistance |
<20 | mΩ | |
12 | Self Consumption |
Working current | 35 | mA | |
Sleeping current( over-discharge) | 800 | uA | |||
13 | Working Temp | Temp range | -20~70 | ℃ | |
Storing Temp | Temp range | -40~80 | ℃ |
Wiring operation
1. First connect the B-cable of the protection board to the total negative pole of the battery pack.
2. The cable starts from the thin black one connecting B-, the second red cable connects the
positive pole of the first string of batteries, and the next string is connected in turn. The positive pole of the pool and then insert the cable into the protection board.
3. After finishing the wiring soldering, measure whether the battery B+, B-voltage and P+,P-voltage values are the same, the protection board works positively.
4. When removing the protection board, first pull out the cable (if there are two cables, pull the
high-voltage cable first, then pull the low-voltage cable), then remove Power cable B-.